TL;DR for operators

A perfect hallucination-localization score need not mean that an AI system has identified the complete erroneous passage. In one diagnostic experiment, predictions recovered just 3.1% of annotated error characters while receiving a perfect score under a containment-based metric.

The underlying issue is broader than one metric. Hallucination benchmarks differ in how examples are constructed, what counts as an error, which evidence is available, and whether systems must classify responses, highlight passages, or verify claims. These choices determine what evaluation scores mean.

For organizations selecting hallucination detectors or monitoring retrieval-augmented generation (RAG), the relevant question is whether a benchmark rewards the behavior needed for a specific intervention. Containment scores should be accompanied by overlap-sensitive measures, and evaluations should disclose their annotation and evidence rules. The research demonstrates why these precautions matter, but does not establish that adopting them improves production reliability.

A perfect score with almost no error recovered

Consider an AI monitoring system that highlights suspicious text within a generated answer. Its evaluation reports perfect localization. An engineer investigating the answer might reasonably expect the highlighted region to identify the erroneous content.

But what if the highlight covers only one character inside a much longer erroneous passage?

That is precisely the limitation demonstrated by Julia Belikova and Elisei Rykov in Mycelium: A Meta-Study of Hallucination Detection Across Provenance, Typology, and Granularities.1

Their diagnostic constructs a one-character prediction inside each annotated hallucination span. Under the proposed Span Coverage F1 metric, these predictions receive 1.000, the maximum possible score. Yet they recover only 3.1% of reference characters on average. Character intersection-over-union (IoU), which measures textual overlap relative to the combined span extent, is just 0.031.

The two scores are not computationally inconsistent. They answer different questions.

One asks whether the predicted region falls entirely within an annotated error. The other measures how much of the annotated region was recovered relative to the combined extent.

If a downstream system must identify the complete erroneous proposition before correcting it, containment alone may be insufficient. The experiment establishes this measurement limitation, although it does not test an actual correction workflow.

What counts as hallucination depends on the benchmark

Mycelium’s central contribution is a framework for understanding why scores labeled hallucination detection may represent different capabilities.

The authors classify benchmarks along three dimensions.

Dimension What changes Consequence for evaluation
Provenance Whether errors arise naturally, are deliberately elicited or selected, or are synthetically constructed Evaluated failures may differ from those encountered in deployment
Typology Whether labels identify any error or distinguish contradictions, unsupported claims, substitutions, and other categories The definition of correct detection changes
Granularity Whether the evaluation unit is a full response, a text span, an individual claim, or multiple levels The required detector output and scoring rule change

These distinctions matter even when two systems report the same metric name.

A detector evaluated on synthetic factual substitutions may perform differently on naturally occurring unsupported reasoning. A response-level classifier may correctly identify a problematic answer without locating the sentence responsible.

Likewise, factuality and faithfulness are distinct. A generated statement can be true according to world knowledge but unsupported by the retrieved documents supplied to a RAG system. Conversely, a statement can accurately reflect an erroneous source while remaining factually incorrect.

The evidence defining correctness therefore needs to be explicit.

The paper formalizes this dependence in Section 2, Equation (1): a detector’s reported score is an expectation under a benchmark-specific distribution, scoring rule, and procedure for aligning the detector’s output with the required evaluation format.

That alignment matters. A response-level judgment cannot become reliable claim-level verification simply through relabeling; another decomposition or localization procedure is required.

Changing the reference can change the score without changing the prediction

The empirical component examines 154 English examples from Mu-SHROOM, containing 1,665 annotator-level hallucination span sets.

Different annotators may identify the same erroneous content while selecting different boundaries. Among 6,280 eligible non-empty, non-identical annotation pairs, 1,403 pairs (22.3%) exhibit nested boundaries while preserving the same number of connected spans.

The authors investigate this disagreement through a leave-one-annotator-out evaluation. One annotator’s spans are treated as predictions, while annotations from the remaining people form alternative references:

  • Majority reference: characters annotated as erroneous by a strict majority of the remaining annotators.
  • Union reference: characters annotated as erroneous by at least one remaining annotator.

The predictions stay unchanged. Only the reference construction changes.

Metric Majority Union Change
Span Coverage F1 0.410 0.750 +0.340
Exact span F1 0.288 0.071 −0.217
Character F1 0.653 0.568 −0.085
Character IoU 0.561 0.462 −0.099
DetEval-1D 0.574 0.239 −0.335
CLEval-1D 0.626 0.559 −0.067

Source: Section 3.2, Table 1. All scores are macro-averaged; changes equal union minus majority.

The results show divergent responses to the same reference change.

Union references generally expand annotated error regions. That makes it easier for a predicted span to fit entirely inside a reference, increasing containment-based coverage. But expanded references can reduce exact-boundary agreement and character-overlap scores.

The improvement from 0.410 to 0.750 therefore reflects changed evaluation conditions, not a detector becoming more capable.

Neither annotation aggregation rule is independently established as the correct ground truth. The experiment isolates measurement sensitivity rather than comparing trained detectors.

Span Coverage F1 rewards containment, not completeness

The paper proposes Span Coverage F1 because conventional metrics can penalize narrower predicted regions even when those regions remain inside broader human annotations.

Its two components are:

  • Prediction coverage: the fraction of predicted spans fully contained within at least one reference span.
  • Reference coverage: the fraction of reference spans containing at least one predicted span.

Their harmonic mean produces Span Coverage F1.

This design deliberately tolerates inward boundary refinements. On the selected nested-boundary diagnostic subset of 376 cases, Span Coverage F1 reaches 1.000, compared with 0.032 for exact span F1.

That is an intended property of the metric, not evidence of superior detector performance.

The paper also checks cases where predicted and reference spans overlap without containment. Span Coverage F1 falls to 0.347 for partial overlaps and reaches zero for disjoint annotations. These diagnostics clarify the specific relationship the metric rewards.

The one-character stress test exposes the corresponding weakness: if every reference span contains a prediction, even a single character can satisfy the containment requirement.

For evaluation designers, the distinction is consequential. If identifying a valid subregion is sufficient, containment may be appropriate. If correcting or removing an entire erroneous statement requires greater textual coverage, character F1 or IoU provides information that containment omits.

The metrics are complementary because they encode different definitions of successful localization.

Detector architecture introduces another comparability problem

Mycelium also synthesizes hallucination-detection approaches according to their access requirements, supervision, output representations, and calibration procedures.

Black-box detectors operate without direct access to a generator’s internal activations. They can therefore be applied to closed models, but may require external retrieval, repeated generation, or additional judge-model calls.

White-box detectors use internal model information. Their applicability depends on access to compatible representations, limiting portability across some model architectures and deployment arrangements.

Neither access category establishes universal superiority.

Supervision sources, calibration thresholds, claim-decomposition procedures, and aggregation rules can also affect reported results.

For example, a claim-level verifier’s apparent accuracy depends partly on which propositions an extraction system makes available for verification. Filtering difficult or non-atomic claims changes the evaluated population.

The review identifies these dependencies conceptually. It does not experimentally establish which architecture transfers best across production settings.

Define the intervention before choosing the score

The Cognaptus interpretation is that hallucination evaluation should start with the action the organization expects to take after detecting an error.

For a RAG quality-assurance owner deciding whether an answer is supported by retrieved documents, the evaluation should prioritize source faithfulness. External factual verification becomes a separate objective when correctness beyond the supplied documents is required.

For a monitoring owner deciding whether to flag an entire response, response-level detection may provide the necessary signal. When the next step is removing an unsupported claim or correcting a passage, span- or claim-level evaluation becomes relevant.

For a procurement lead comparing commercial detectors, benchmark results are interpretable only when error definitions, evidence availability, evaluation units, calibration, and scoring procedures are sufficiently compatible.

A defensible evaluation record should therefore specify the target failure, dataset provenance, annotation policy, detector access requirements, output transformations, and complementary metrics. Containment and character overlap should be displayed together when both correct placement and recovery extent matter.

These are recommendations derived from the paper’s measurement framework, not experimentally validated improvements in vendor selection or monitoring effectiveness.

What the evidence does not establish

The strongest empirical conclusion is that annotation construction and metric semantics can substantially alter localization scores.

The evidence comes from one English-language benchmark, with human annotation sets serving as predictions. The study does not demonstrate improvements from training a hallucination detector, nor does it establish equivalent behavior across languages, domains, or annotation protocols.

Its broader literature synthesis is not a documented systematic review or statistical meta-analysis.

Most importantly, no deployment experiment connects the alternative scores to end-user accuracy, correction costs, agent reliability, or business outcomes.

Organizations should therefore separately test whether a chosen metric predicts the success of the intervention it is intended to support.

The score is only as meaningful as the error it measures

Mycelium provides a disciplined way to interpret hallucination-detection results: identify how errors enter the benchmark, what labels mean, which units are evaluated, and what the metric actually rewards.

Its most revealing result is also its simplest. A perfect localization score can coexist with almost no recovery of the annotated erroneous text.

For AI quality governance, the objective is not to select the most impressive number. It is to establish that the number measures the detection behavior required for the next operational decision.

Cognaptus: Automate the Present, Incubate the Future.


  1. Julia Belikova and Elisei Rykov (2026). Mycelium: A Meta-Study of Hallucination Detection Across Provenance, Typology, and Granularities. arXiv:2610.33608. https://arxiv.org/abs/2610.33608 ↩︎